Evaluation of omega-shaped Coriolis mass flow meter for laminar flow | ||
Journal of Computational & Applied Research in Mechanical Engineering (JCARME) | ||
مقاله 5، دوره 13، شماره 2 - شماره پیاپی 26، خرداد 2024، صفحه 181-190 اصل مقاله (786.98 K) | ||
نوع مقاله: Research Paper | ||
شناسه دیجیتال (DOI): 10.22061/jcarme.2023.9064.2223 | ||
نویسندگان | ||
Vikram Ashok Kolhe* 1؛ Vishal D Chaudhari2؛ Suyash Yashwant Pawar3؛ Ravindra L Edlabadkar4؛ Kailas Chandratre5 | ||
1Late G.N. Sapkal College of Engineering, Department of Mechanical Engineering, Nashik, Maharashtra, India | ||
2Cusrow Wadia Institute of Technology, Department of Mechanical Engineering, Pune, Maharashtra, India | ||
3MVPS’s KBT College of Engineering, Department of Mechanical Engineering, Nashik, Maharashtra, India | ||
4PVG's College of Engineering and Technology, Department of Mechanical Engineering, Pune, Maharashtra, India | ||
5KVN NSPS’s LGM Institute of Engineering Education and Research, Department of Mechanical Engineering, Nashik, Maharashtra, India | ||
تاریخ دریافت: 04 خرداد 1401، تاریخ بازنگری: 19 تیر 1402، تاریخ پذیرش: 20 تیر 1402 | ||
چکیده | ||
Measuring flow rate precisely in laminar flow has been a difficult task, especially when utilizing a Coriolis mass flow meter (CMFM) for low flow rate measurements. The meter often under reads the mass flow rate, making it less useful in these conditions. The dominant factor affecting the CMFM's performance in laminar regions is secondary flow, which overshadows the generated Coriolis force, leading to an under-reading of flow rate. Previous studies have indicated that tube curvature is the most significant parameter affecting secondary flow generation and the overall performance of the meter. An omega-shaped tube configuration featuring a continuous curvature has been identified as the optimal shape for maximizing a CMFM device’s performance in laminar flow. The purpose of the investigation is to study and compare the efficiency of various Omega tube designs that have undergone slight geometric alterations. Four different configurations were evaluated for maximum time lag by vibrating at their respective natural frequencies and keeping the sensor position along the centerline of the tube configuration. | ||
کلیدواژهها | ||
Coriolis mass flow meter؛ Omega tube configuration؛ Fluid-structure interaction؛ Experimentation؛ Laminar flow regime | ||